IEC 61850 Sampled Value Input IEDs
© Copyright Rod Hughes Consulting Pty Ltd
| Rod Hughes Consulting General Web Site | Applications Home | Innovations and Solutions Home | A bit about Rod Hughes |
|
|---|
Note - if the navigation pane on the left of this window is not visible, click the 2-pane icon on the top bar
There are a growing number of IEDs that can accept the IEC 61850 9-2LE input, and now IEC 61869-9. some of which are listed below (if you want your IED included, contact me by email with suitable information).
The IEDs below are promoted by the vendor concerned as supporting Sampled Value inputs to the interim "LE" Guideline, or now the official IEC 61869-9. As IEC 61850-9-2LE is now defunct, please check with the vendors if they now support the official Standard IEC 61869-9.
There are a number of significant interoperability issues between the interim "LE" Guideline and the official IEC Standard, notably amongst others, the LE "samples per cycle" has changed to IEC "samples per second" and the rates are different so please check carefully.
Blank cell means I have no feedback/intelligence received from the supplier to date - they may well have applications available and they are welcome to advise me accordingly to update the table.
| Vendor | Distance | Line | Transformer | Busbar | Multifunction | Bay control, | Overcurrent | Meters | 9-2 Accuracy Test Set | Merging Units for Conventional CT/VT | Optical CT Sensor |
|---|---|---|---|---|---|---|---|---|---|---|---|
| L&G | E880 | ||||||||||
| EDMI | |||||||||||
| Schneider * | P443 P444 | P545 P546 | P643 P645 | P746 | |||||||
| GE Micom * | P443 | P545 | P643 | P746 | P841 | ||||||
| GE UR | |||||||||||
| ABB | REL 670 | RED 670 RED 615 | RET 670 | REB 500 | REX 640 | REC 670 | REF 620 REF 601 REJ 603 | ||||
| NARI | PCS-902 | PCS-931 | PCS-978 | PCS-915 | PCS-9611 | PCS-221 | |||||
| ZIV | Q4/2012 | Q4/2012 | Q4/2012 | ||||||||
| SEL | SEL-421-7 | SEL-487E-5 | SEL-451-6 | SEL-401 | |||||||
| ALSTOM * | P44 P446 | P546 | P645 | P746 | P841 | ||||||
| Siemens | 7SC805 | ||||||||||
| Beckwith | |||||||||||
| ERLPhase | |||||||||||
| Basler | |||||||||||
| Protech | |||||||||||
| Toshiba | |||||||||||
| SATEC | EM720 | ||||||||||
| ZERA | WM3000U WM3000 I | ||||||||||
| Schniewindt | SAMU | ||||||||||
| RT Measurement Technologies | MU320 | ||||||||||
| Wasion | DSAD331 | ||||||||||
| Arteche | SDO OCT | ||||||||||
| Hμ | OSF | ||||||||||
| VIZIMAX | AMU |
* Note: It seems that Schneider and GE have the same MiCOM product range names (due to previous common AREVA history) but the IEDs manufactured after the organisation split may be slightly different in features and capabilities which should be checked with your local sales representatives.
Copy this permanent link to this page https://rhconsult.tiny.us/2p8sjzcd
Contact Me
A phone call is nearly always welcome depending on the time of night wherever I am in the world.
Based in Adelaide UTC +9:30 hours e.g.
| April-September | Noon UK = 2030 Adelaide |
| October-March: | Noon UK = 2230 Adelaide |
Mobile + 61 419 845 253