CIGRE provides a wealth of technical reference material available from their on-line library (Members can download for free) http://www.e-cigre.org/
The following information is specifically relevant to the application of IEC 61850. A more complete listing of Technical Brochures is listed here
Technical Brochure | Published | Title |
---|---|---|
246 | 2004 | Automation Of New And Existing Substations: Why And How, |
326 | 2007 | Introduction Of IEC 61850 And Its Impact On Protection And Automation Within Substations, |
329 | 2007 | Guidelines For Specification And Evaluation Of Substation Automation Systems, |
401 | 2010 | Functional Testing Of IEC 61850 Based Systems, |
404 | 2010 | Acceptable Functional Integration in HV Substations, |
419 | 2010 | Treatment of Information Security, |
427 | 2010 | Impact of Implementing Cyber Security Requirements Using IEC 61850, |
464 | 2011 | Maintenance Strategies for Digital Substation Automation Systems, |
466 | 2011 | Engineering Guidelines for IEC61850, |
540 | 2013 | Applications of IEC 61850 Standard to Protection Schemes |
584 | 2014 | Implications and Benefits of Standardised Protection and Control Schemes |
603 | 2014 | Application and management of cyber security measures for Protection & Control systems |
628 | 2015 | Documentation Requirements From Design To Operation To Maintenance For Digital Substation Automation Systems |
Contact Me
A phone call is nearly always welcome depending on the time of night wherever I am in the world.
Based in Adelaide UTC +9:30 hours e.g.
April-September | Noon UK = 2030 Adelaide |
October-March: | Noon UK = 2230 Adelaide |
  Mobile + 61 419 845 253
Extra Notes:
No Waiver, No Licence:
Rod Hughes Consulting Pty Ltd accepts no direct nor consequential liability in any manner whatsoever to any party whosoever who may rely on or reference the information contained in these pages. Information contained in these pages is provided as general reference only without any specific relevance to any particular intended or actual reference to or use of this information. Any person or organisation making reference to or use of this information is at their sole responsibility under their own skill and judgement.
This page is protected by Copyright ©
Beyond referring to the web link of the material and whilst the information herein is accessible "via the web", Rod Hughes Consulting Pty Ltd grants no waiver of Copyright nor grants any licence to any extent to any party in relation to this information for use, copy, storing or redistribution of this material in any form in whole or in part without written consent of Rod Hughes Consulting Pty Ltd.