IEC Standards
IEC 61850 was issued in 2002-2004 with some 1700 pages across some nine parts
There are now some 70 identifiable Parts of the Standard, over 30 of which are published current versions - some Edition 2, some Edition 1 and some work in progress as Ed1 or Ed2 or Ed "n"
This gives a snapshot of the various Parts and status as mentioned by the IEC
The subsequent table provides a list of Parts of other Standards that are directly applicable to IEC 61850 applications or vice versa.
Note that just because a particular Part has been issued as a new Edition of an old Edition, this does not mean you don't need to reference the old Edition from time to time i.e.. your library of accessible Standards may need to have all Editions!
The list may be slightly out of date as it is only maintained from time-to-time.
Please check the IEC Webstore (or via your own national Standards body) to buy the latest (and old) versions https://webstore.iec.ch/searchform&q=61850# .
Types of IEC documents
- International Standards (IS):
A normative document, developed according to consensus procedures, which has been approved by the IEC National Committee members of the responsible committee in accordance with Part 1 of the ISO/IEC Directives.
https://www.iec.ch/publications/international-standards - Technical Specifications (TS):
These are often published when the subject under question is still under development or when insufficient consensus for approval of an International Standard is available. Technical Specifications approach International Standards in terms of detail and completeness, but have not yet passed through all approval stages either because consensus has not been reached or because standardization is seen to be premature.
https://www.iec.ch/publications/specifications - Publicly available specification (PAS):
These respond to an urgent market need in areas of rapidly evolving technology.
Competing publicly available specifications on the same subject are permitted.
https://www.iec.ch/publications/specifications - Technical Reports (TR):
These are entirely informative in nature and shall not contain matter implying that they are normative.
https://www.iec.ch/publications/technical-reports
Reference | Type | Current | Old | Title |
---|---|---|---|---|
IEC 61850-1 | TR | 2013 | 2003 | Introduction and overview |
IEC 61850-1-2 | TS | 2020 | Guideline on extending IEC 61850 | |
IEC 61850-2 | TS | 2019 | 2003 | Glossary |
IEC 61850-3 | IS | 2013 | 2002 | General requirements |
IEC 61850-4 | IS | 2011 | 2002 | System and project management |
IEC 61850-5 | IS | 2013 | 2003 | Communication requirements for functions and device models |
IEC 61850-6 | IS | 2018 | 2009 2004 | Configuration description language for communication in electrical substations related to IEDs |
IEC 61850-6-1 | ||||
IEC 61850-6-2 | Configuration description language for extensions for human machine interfaces | |||
IEC 61850-6-100 | SCL Function Modelling for Substation Automation | |||
IEC 61850-7-1 | IS IS IS | 2011 Amd 1 2020 CSV 2020 | 2003 | Basic communication structure - Principles and models |
IEC 61850-7-2 Ed2 AMD1 IEC 61850-7-2 Ed2.1 | IS IS CSV | 2019 2020 2020 | 2010, | Basic information and communication structure - Abstract communication service interface (ACSI) |
IEC 61850-7-3 Ed2 AMD1 IEC 61850-7-3 Ed2.1 | IS IS CSV | 2019 2020 2020 | 2010, 2003 | Basic communication structure - Common data classes |
IEC 61850-7-4 Ed2 AMD1 IEC 61850-7-4 Ed2.1 | IS IS CSV | 2019 2020 2020 | 2010, 2003 | Basic communication structure - Compatible logical node classes and data object classes |
IEC 61850-7-5 | TR | 2021 | IEC 61850 modelling concepts | |
IEC 61850-7-6 | TR | 2019 | Guideline for definition of Basic Application Profiles (BAPs) using IEC 61850 | |
IEC 61850-7-7 | TS CSV | 2018 2023 | Machine-processable format of IEC 61850-related data models for tools | |
IEC 61850-7-99 | ||||
IEC 61850-7-410 | 2015 | 2012, 2007 | Basic communication structure - Hydroelectric power plants - Communication for monitoring and control | |
IEC 61850-7-420 | IS | 2009 | Basic communication structure - Distributed energy resources logical nodes | |
IEC 61850-7-499 | ||||
IEC 61850-7-500 | TR | 2017 | Basic information and communication structure - Use of logical nodes for modelling application functions and related concepts and guidelines for substations | |
IEC 61850-7-510 | TR | 2012 | Hydroelectric power plants - Modelling concepts and guidelines | |
IEC 61850-7-520 | DER - Modelling concepts and guidelines | |||
IEC 61850-8-1 | IS | 2020 | 2011 2004 | Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
IEC 61850-8-2 | IS | 2018 | Specific communication service mapping (SCSM) - Mapping to Extensible Messaging Presence Protocol (XMPP) | |
withdrawn | 2003 | Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link | ||
IEC 61850-9-2 | IS | 2020 | 2011 2004 | Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3 |
UCAIUG | refer IEC 61860-9 | 2007, 2001 | UCAIUG's Interim Guideline for application of IEC 61850-9-2 for CT/VT applications. Replaced by IEC 61869-9 | |
IEC 61850-9-3 | IS | 2016 | Precision time protocol profile for power utility automation (IEEE 1588) | |
IEC 61850-10 | IS | 2012 | 2005 | Conformance testing |
IEC 61850-10-3 | Functional testing of IEC 61850 based systems | |||
IEC 61850-80-1 | TS | 2016 | 2008 | Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104 |
IEC 61850-80-2 | TS | Mapping to DNP3 IEEE Standard 1815.1 IEEE Standard for Exchanging Information Between Networks Implementing IEC 61850 and IEEE Std 1815(TM) [Distributed Network Protocol (DNP3)] | ||
IEC 61850-80-3 | TR | 2015 | Mapping to web protocols - Requirements and technical choices | |
IEC 61850-80-4 | TS | 2016 | Translation from the COSEM object model (IEC 62056) to the IEC 61850 data model | |
IEC 61850-80-5 | TS | Guideline for mapping information between IEC 61850 and IEC 61158-6 (Modbus) | ||
IEC 61850-80-6 | Using IEC 61850 for communication between substations and control centres | |||
IEC 61850-80-7 | Communication services and data model to support IEC 61850 system management | |||
IEC 61850-90-1 | TR | 2010 | Use of IEC 61850 for the communication between substations | |
IEC 61850-90-2 | TR | 2016 | Using IEC 61850 for communication between substations and control centres | |
IEC 61850-90-3 | TR | 2016 | Using IEC 61850 for condition monitoring diagnosis and analysis | |
IEC 61850-90-4 | TR | 2020 | 2013 | Network engineering guidelines |
IEC 61850-90-5 | TR | 2012 | Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118 | |
IEC 61850-90-6 | TR | 2018 | Use of IEC 61850 for Distribution Automation Systems | |
IEC 61850-90-7 | TR | 2013 | Object models for power converters in distributed energy resources (DER) systems | |
IEC 61850-90-8 | TR | 2016 | Object model for E-mobility | |
IEC 61850-90-9 | TR | 2020 | Object models for electrical storage systems | |
IEC 61850-90-10 | TR | 2017 | Models for scheduling | |
IEC 61850-90-11 | TR | 2020 | Methodologies for modelling of logics for IEC 61850 based applications | |
IEC 61850-90-12 | TR | 2020 | 2015 | Wide area network engineering guidelines |
IEC 61850-90-13 | TR | Deterministic networking technologies | ||
IEC 61850-90-14 | TR | Using IEC 61850 for FACTS and power conversion data modelling | ||
IEC 61850-90-15 | TR | DER Grid Integration | ||
IEC 61850-90-16 | TR | 2021 | Requirements of system management for Smart Energy Automation | |
IEC 61850-90-17 | TR | 2017 | Using IEC 61850 to transmit power quality data | |
IEC 61850-90-18 | Modelling alarm handling for IEC 61850 | |||
IEC 61850-90-19 | TR | Applying Role Based Access Control (RBAC) to IEC 61850 | ||
IEC 61850-90-20 | TR | Guideline for redundant IEDs with IEC 61850 | ||
IEC 61850-90-21 | Use of IEC 61850 for travelling wave fault location system | |||
IEC 61850-90-22 | TR | SCD based substation network auto-routing with visualization and supervision support | ||
IEC 61850-90-23 | Model extensions to IEC 61850 to support microgrids | |||
IEC 61850-90-24 | Mapping of IEC 62351-7 on IEC 61850 | |||
IEC 61850-90-25 | Model update based on Users feedback | |||
IEC 61850-90-26 | IED Specification Description | |||
IEC 61850-90-27 | Use of IEC 61850 for thermal energy systems connected to electric power grid | |||
IEC 61850-90-28 | Validation specification for GOOSE and SV | |||
IEC 61850-90-29 | Physical interfaces of an Intelligent Electronic Device (IED) and its connectivity | |||
IEC 61850-99-99 | TR | Communication network in hydropower plants |
Reference | Type | Current | Old | Title |
---|---|---|---|---|
IEC 61131 series | IS | Programmable controllers | ||
IEC 61499 series | IS | Function blocks | ||
IEC 61400-25-1 | IS | 2017 | 2006 | Communications for monitoring and control of wind power plants – Overall description of principles and models |
IEC 61400-25-2 | IS | 2015 | 2006 | Communications for monitoring and control of wind power plants - Information models |
IEC 61400-25-3 | IS | 2015 | 2006 | Communications for monitoring and control of wind power plants - Information exchange models |
IEC 61400-25-4 | IS | 2016 | 2008 | Communications for monitoring and control of wind power plants - Mapping to communication profile |
IEC 61400-25-5 | IS | 2017 | 2006 | Communications for monitoring and control of wind power plants - Compliance testing |
IEC 61400-25-6 | IS | 2016 | Communications for monitoring and control of wind power plants - Logical node classes and data classes for condition monitoring | |
IEC 61869-6 | 2016 | Additional general requirements for low-power instrument transformers | ||
IEC 61869-9 | 2016 | Digital interface for instrument transformers (Replaces interim guideline "UCAIUG IEC 61850-9-2LE") | ||
IEC 61869-13 | Stand Alone merging Unit | |||
IEC 61968-1 | Application integration at electric utilities – System interfaces for distribution management Interface architecture and general recommendations | |||
IEC 61968-2 | Application integration at electric utilities – System interfaces for distribution management - Glossary | |||
IEC 61968-3 | Application integration at electric utilities – System interfaces for distribution management - Interface for network operation | |||
IEC 61968-4 | Application integration at electric utilities – System interfaces for distribution management - Interface for records and asset management | |||
IEC 61968-5 | Application integration at electric utilities – System interfaces for distribution management - Interface standard for operational planning and optimisation | |||
IEC 61968-6 | Application integration at electric utilities – System interfaces for distribution management - Interface for maintenance and construction | |||
IEC 61968-7 | Application integration at electric utilities – System interfaces for distribution management - Interface standard for network extension planning | |||
IEC 61968-8 | Application integration at electric utilities – System interfaces for distribution management - Interface standard for customer support | |||
IEC 61968-9 | Application integration at electric utilities – System interfaces for distribution management - Interface for meter reading and control | |||
IEC 61968-11 | Application integration at electric utilities – System interfaces for distribution management - Common information model (CIM) extensions for distribution | |||
IEC 61968-13 | Application integration at electric utilities – System interfaces for distribution management - CIM RDF model exchange format for distribution | |||
IEC 61968-100 | Ipplication integration at electric utilities – System interfaces for distribution management - Implementation profiles | |||
IEC 62271-3 | 2015 | 2006 | High-voltage switchgear and controlgear: Digital interfaces based on IEC 61850 | |
IEC 62351-1 | TS | 2007 | Power systems management and associated information exchange - Data and communications security: Communication network and system security - Introduction to security issues | |
IEC 62351-2 | 2023 | Communication network and system security - Profiles including TCP/IP | ||
IEC 62351-6 | TS | 2007 | Power systems management and associated information exchange - Data and communications security: Security for IEC 61850 | |
IEC 62351-9 | 2023 | Cyber security key management for power system equipment | ||
IEC 62351-100-4 | 2023 | Cybersecurity conformance testing for IEC 62351-4 | ||
IEC 62357-1 | TR | 2016 | 2012 | Power systems management and associated information exchange: Reference architecture |
IEC 62357-200 | TR | 2015 | Power systems management and associated information exchange: Guidelines for migration from Internet Protocol version 4 (IPv4) to Internet Protocol version 6 (IPv6) | |
IEC 62361-2 | 2013 | Power systems management and associated information exchange - Interoperability in the long term: End to end quality codes for supervisory control and data acquisition (SCADA) | ||
IEC 62689-100 | TR | 2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes: Requirements and proposals for the IEC 61850 series data model extensions to support fault passage indicators applications | |
IEC TS 63266 | TS | 2023 | Representation of communication in power utility automation |
Relevant Non-IEC Standards
Reference | Title |
---|---|
IEEE 1686 | IEEE Standard for Substation Intelligent Electronic Devices (IEDs) Cyber Security Capabilities |
Please copy this permanent link to this page: https://rhconsult.tiny.us/mse8wmcm
- Protection Systems Engineering
- IEC 61850 Engineering
I provide a range of courses for company-specific in-house training and occasional public invitation courses. Contact me for details.
Contact Me
A phone call is nearly always welcome depending on the time of night wherever I am in the world.
Based in Adelaide UTC +9:30 hours e.g.
April-September | Noon UK = 2030 Adelaide |
October-March: | Noon UK = 2230 Adelaide |
Mobile + 61 419 845 253
Extra Notes:
Rod Hughes Consulting Pty Ltd accepts no direct nor consequential liability in any manner whatsoever to any party whosoever who may rely on or reference the information contained in these pages. Information contained in these pages is provided as general reference only without any specific relevance to any particular intended or actual reference to or use of this information. Any person or organisation making reference to or use of this information is at their sole responsibility under their own skill and judgement.
No Waiver, No Licence:
This page is protected by Copyright ©
Beyond referring to the web link of the material and whilst the information herein is accessible "via the web", Rod Hughes Consulting Pty Ltd grants no waiver of Copyright nor grants any licence to any extent to any party in relation to this information for use, copy, storing or redistribution of this material in any form in whole or in part without written consent of Rod Hughes Consulting Pty Ltd.