Remote Access to any IED
Rod Hughes Consulting General Web Site | Applications Home | Innovations and Solutions Home | A bit about Rod Hughes |
|
---|
Note - if the navigation pane on the left of this window is not visible, click the 2-pane icon on the top bar
The "5 minute remote restoration" DCU solution was presented as Contributions to SCB3 and SCB5 at CIGRE 2012 - refer My Papers and Contributions RH17, RH18 and RH19
Regardless of the capability/availability of the corporate WAN, in some cases for various reasons it can be advantageous to have a separate access system that provides the FULL range of IED access regardless of what PC or device is being used by the engineer or technician.
The technicians and engineers require highly secure access to remote sites and the IEDs located within them.
The technician must access the right substation and then assess the ability to undertake remote access in consideration of which:
- vendor’s IEDs are installed?
- X system
- Y system
- Condition Monitoring
- HMI platform
- Vendor A, B … or Z HMI “standard”
- Installed last year or 20 years ago
- DOS, Windows 3.1 / 3.11 / NT / XP / 7 …(… Windows42)
- IED firmware versions
- IED setting files versions
- IED setting software operating platform
- DOS, Windows 3.1 / 3.11 / NT / XP / 7 …(… Windows42)
- IED setting software version is required?
- Remotely operated isolation and test equipment?
All through common access point and procedure!
Importantly, the technician needs to use all the CORRECT software tools relevant to those IEDs on site - no more worrying about whether the engineer/technician has the appropriate version on their PC or Tablet, perhaps is even using a generic home/private PC with no IED tools loaded at all.
Simply by using the internet to connect to the central server via their secure login, all the available sites need to be displayed.
Once the site is accessed, all the available software tools installed for that site (obviously specific and up-to-date to the IEDs on that site) can be used to access the relevant IEDs using the FULL power of the vendor's tools.
- Measurements and status inputs can be read,
- Parameters retrieved
- Records and logs retrieved
- Settings changed (where policy and configurations permit)
- Access drawings and documentation stored on the site DCU
- even updating the version of the vendor's software tool installed at site
... all as if the technician/engineer was standing in the substation.
The technician/engineer can connect whilst in the office, at home or at another substation - anywhere there is an internet connection - even from smart phones and tablets.
Contact Me
A phone call is nearly always welcome depending on the time of night wherever I am in the world.
Based in Adelaide UTC +9:30 hours e.g.
April-September | Noon UK = 2030 Adelaide |
October-March: | Noon UK = 2230 Adelaide |
Mobile + 61 419 845 253
Extra Notes:
No Waiver, No Licence:
Rod Hughes Consulting Pty Ltd accepts no direct nor consequential liability in any manner whatsoever to any party whosoever who may rely on or reference the information contained in these pages. Information contained in these pages is provided as general reference only without any specific relevance to any particular intended or actual reference to or use of this information. Any person or organisation making reference to or use of this information is at their sole responsibility under their own skill and judgement.
This page is protected by Copyright ©
Beyond referring to the web link of the material and whilst the information herein is accessible "via the web", Rod Hughes Consulting Pty Ltd grants no waiver of Copyright nor grants any licence to any extent to any party in relation to this information for use, copy, storing or redistribution of this material in any form in whole or in part without written consent of Rod Hughes Consulting Pty Ltd.